Integral Values & Characteristics
Integral Values condenses a whole spectrum into the single weighted-average
numbers that spec sheets quote: visible transmittance, solar reflectance, and
so on. For each weighting it averages T(λ), R(λ) or A(λ) over a wavelength band,
weighting each wavelength by a light source times a detector response. Alongside
the built-in standards you can build your own integral from any source, detector
and band. These figures describe the filter as a whole, so they follow the
design’s evaluation mode, whether that is the front
surface, the back surface, or the complete front–substrate–back system, as the Eval
badge under the chart shows. For the usual whole-part figures such as solar or photopic
transmittance, evaluate the design as the total system.
Settings
Section titled “Settings”λ range / step: the wavelength grid the spectrum is sampled on, in nanometres. Every row is integrated over its own whole band, so the grid has to span the band of each integral you want to read. A row whose band the spectrum does not span reads n/a, with the span the spectrum does cover shown beside its band, and the CSV export leaves its cells empty; it is never averaged over the part of the band that happens to be covered. The grid always ends on the end wavelength: a step that does not divide the range adds one shorter last interval. The default grid, 300-2500 nm, covers every built-in row: photopic 380-780 nm, solar 300-2500 nm, UV 300-380 nm and NIR 780-2500 nm.
AOI / pol: angle of incidence and polarization (s, p, or averaged).
Environment: on a design with more than one environment, the Environment droplist in the row under the chart says which one the integrals are computed in. Current follows the environment the Design Editor and the ribbon show. An environment picked by its number and name holds the window on that one, even while it is switched off. All computes every environment that is on: the table lists each integral in every environment, one row each with the environment named after the integral, and the chart draws the selected integral’s channel in each environment, in its own color from the window’s Palette in Preferences > Analysis, without the minimum and maximum marks, which the table gives for each environment. The CSV has the same rows. The material range notice reads the materials of every environment shown. The choice belongs to this window and is not saved with the design.
+ Custom integral… opens a dialog in which you define a weighted average of your own:
Name: what the row is called. It starts as a short name made of the channel, source and detector, such as T·D65·V(λ), selected so that typing replaces it, and it follows those choices until you type in it. A suggested name another custom integral already has gets #2, #3. An integral with no name cannot be added.
Channel: whether to average T, R or A.
Source: the illuminant: D65, D50, illuminant A, AM1.5G solar, equal-energy E, a blackbody at a temperature you set, or a custom table. A blackbody exposes a temperature field; a custom source offers Edit table…, which opens the curve editor on the source spectrum as a weight against wavelength.
Detector: the observer or sensor response: the photopic curve V(λ), a flat response, or a custom table.
Band: the wavelength range (in nm) over which the average is taken.
Add puts the integral in the table as a new row. A custom row reads like a built-in one, with what it integrates dimmed after its name: the channel, then source × detector, such as R · Blackbody 3000 K × Flat (unity). The pencil beside the row, or a double-click on it, opens the same dialog on it to change any of it, its source and detector included; OK applies the changes and the row keeps its place. The trash removes it. Custom integrals are saved and restored automatically. An operand already built from a custom integral in the Merit Function Editor keeps the values it was built with.
A custom table is typed, pasted or read from a file in the curve editor, which reads text the way the spectrum importer does: a decimal comma is kept, and header rows, blank lines and # comment lines are ignored. The wavelength column can be in nm, µm, cm⁻¹ or eV. Apply needs at least two rows with both a wavelength and a weight, and sorts them by wavelength.
How to read it
Section titled “How to read it”Each row shows the weighted average both as a fraction and as a percent, plus the unweighted minimum and maximum of the channel within the band (with the wavelengths where they occur), useful for worst-case checks like “T ≥ 99 % across the band”. Selecting a row draws the overlay chart on the right: the chosen channel in percent together with the normalized weighting curve, so you can see which part of the spectrum dominates the average. The minimum and maximum are marked on the chart.
A note on the visible figures: Tvis matches the photopic luminance only when the source is D65 and the detector is the CIE 1931 2° observer; a perfect white reads 100 %. The photopic rows are integrated on the λ grid like every other row, with the CIE tables interpolated onto it, so a feature narrower than the 5 nm spacing of those tables is counted once the step resolves it. For the Tvis of a narrow notch, set a step well below the notch width.
References
Section titled “References”- ASTM G173-03, Standard Tables for Reference Solar Spectral Irradiances.
- CIE 15:2004, Colorimetry.
- H. A. Macleod, Thin-Film Optical Filters, 5th ed., §12.2.